Bifold FP10P-87DU3 3/2 Solenoid Valve, 316L SS, 24VDC, Ex d IIC, 0-35 Bar G, H2S Service
Bifold Fluid Power FP10P series 3/2 direct-acting solenoid valve with a stainless steel body and an explosion-proof (Ex d) 316L stainless solenoid operator. It runs on 24 VDC and is rated for 0-35 bar G working pressure. The engraved order code ends in "H2S", and the ports are marked 1, 2 and 3. This is a used surplus spare that has not been functionally tested. Sold individually; 1 available.
SPECIFICATIONS (as marked on the unit)
- Manufacturer: Bifold Fluid Power, England (M24 1SW)
- Full order code (engraved on the valve body): FP10P-110-S3-04-32-NU-V-24VDC-87DU3-K85-L93-H2S
- Model No. (nameplate): FP10P-87DU3
- Serial No.: BW1012-0350
- Max working pressure: 0-35 bar G (on the body engraving and the nameplate)
- Voltage: 24 VDC
- Current: 0.237 A (the end of the marking is cut off in the photo)
- Ports: 1, 2, 3 (3-way / 2-position)
- CSA c-us: Class I, Groups B, C & D; Zones 1 & 2; AExd IIC T4; cert. no. 1398692; "Seal not required"
- ATEX: Ex II 2 GD, EEx d IIC T135 °C, cert. no. BAS02ATEX2048; CE 1180
- Enclosure: NEMA 4X, IP66
- Ambient temperature: marked on the nameplate, but the digits are partly worn (see photos)
- Operator housing: cast "BIFOLD ENGLAND 316L"
- Nameplate warnings: "Do not open when an explosive gas atmosphere is present"; cable entry temperature warning; engraved supply-wire temperature warning in English and French
- Country of origin: United Kingdom (England)
- Unit weight: 5.843 lb (scale reading)
SERIES INFORMATION (from Bifold/distributor literature, not marked on this unit)
In the FP10P order code:
- "S3" is the 35 bar maximum pressure operator.
- "04" is the 1/4 in. body-ported size. The thread standard (NPT or BSP) is not marked on the unit.
- "32" means 3-way, 2-position.
- "NU" means normally universal.
- "V" means Viton seals.
Bifold states that FP10P wetted materials meet NACE MR-01-75 as standard.
CONDITION
Clean surplus unit removed from service; the seller has not tested whether it operates. Red plastic plugs cap the ports and a yellow plug caps the conduit entry. The end cap is secured with socket-head screws and a wire. The stainless surfaces show light handling marks, and the nameplate has some ink smudging near the CSA markings.
Installation in hazardous locations must be done by qualified personnel only, following the certification markings and the manufacturer's instructions.